Installing the right control panel
Prerequisites
1. Follow the safety guidelines listed in Safety instructions.
2. Follow the procedure listed in Before working on your system.
3. Remove air shroud.
Steps
1. Align and slide the right control panel into the slot on the system.
2. Route the right control panel cable through the side wall of the system.
NOTE: Route the cable properly to prevent the cable from being pinched or crimped.
3. Connect the right control panel cable to the connector on the system board.
4. Using the screwdriver, tighten the two screws that secure the right control panel to the system.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
Figure 81. Installing the right control panel
Next steps
1. Install the air shroud .
2. Follow the procedure listed in After working inside your system.
Removing the left control panel
Prerequisites
1. Follow the safety guidelines listed in Safety instructions.
2. Follow the procedure listed in Before working on your system.
3. Remove system cover.
Installing and removing system components