EasyManua.ls Logo

Dell PowerEdge R415 - Acoustical Performance

Dell PowerEdge R415
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Dell
26
PowerEdge R415 Technical Guide
Table 7. Acoustical Performance
Configuration @ 23 ± 2 °C
Operating
Mode
L
WA
-UL
(Bels)
L
pA
(dBA)
Prominent
Tones
CPU
RAID
DIMM
Power Supply
1 x AMD 4122
4 core 2.2GHz
Embedded
SAS 6/iR
1 x 1GB
1 x 480W
Non-
redundant
Idle
5.5
39
None
Stressed
5.5
39
None
2 x AMD 4122
4 core 2.2GHz
Embedded
SAS 6/iR
4 x 2GB
2 x 500W
Redundant
Idle
5.6
40
None
Stressed
5.6
40
None
2 x AMD 4184
6 core 2.8GHz
PERC H800
8 x 8GB
2 x 500W
Redundant
Idle
5.9
46
None
Stressed
6.4
46
None
Definitions
Idle: Reference ISO7779 (1999) definition 3.1.7; system is running in its OS but no other specific activity.
Stressed Processor: An operating mode per ISO7779 (1999) definition 3.1.6. The software SPECPower_ssj2008
is utilized to stress the processors. SPECPower is set to 50% loading.
LwA UL: The upper limit sound power level (LwA) calculated per section 4.4.2 of ISO 9296 (1988) and
measured in accordance to ISO 7779 (1999).
LpA: Average bystander A-weighted sound pressure level. The system is placed in a rack with its bottom at
25 cm from the floor. The acoustic transducers are at the four bystander positions, ref ISO7779 (1999)
Section 8.6.2.
Prominent tone: Criteria of D.5 and D.8 of ECMA-74 9th ed. (2005) are followed to determine if discrete
tones are prominent. The system is placed in a rack with its bottom at 75 cm from the floor. The acoustic
transducer is at front bystander position, ref ISO7779 (1999) Section 8.6.2.