EasyManua.ls Logo

Dell POWEREDGE R515 - Page 14

Dell POWEREDGE R515
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12 Getting Started With Your System
Environmental
NOTE: For additional information about environmental measurements for specific
system configurations, see www.dell.com/environmental_datasheets.
Temperature
Operating
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE: For altitudes above 2950 feet,
the maximum operating temperature is
derated 1ºF/550 ft.
Storage
–40° to 65°C (–40° to 149°F) with a
maximum temperature gradation
of 20°C per hour
Relative humidity
Operating
20% to 80% (noncondensing) with
a maximum humidity gradation
of 10% per hour
Storage
5% to 95%, maximum humidity gradation
of 10% per hour.
Maximum vibration
Operating
0.26 G at 5–350 Hz for 15 min
Storage
1.87 G at 10–500 Hz for 15 min
Maximum shock
Operating
One shock pulse in the positive z axis
(one pulse on each side of the system) of
31 G for 2.6 ms in the operational orientation
Storage
Six consecutively executed shock pulses in
the positive and negative x, y, and z axes
(one pulse on each side of the system)
of 71 G for up to 2 ms, and Square Wave
32G, 270in/sec

Other manuals for Dell POWEREDGE R515