EasyManua.ls Logo

Dell PowerEdge R610 - Power Consumption Testing; Maximum Input Amps

Dell PowerEdge R610
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Dell™ PowerEdge™ R610 Technical Guidebook
16
MAXIMUM VIBRATION
Operating
0.26 Grms at 5 – 350Hz for 5 minutes in operational orientations
Storage
1.54 Grms at 10 – 250Hz for 10 minutes in all orientations
MAXIMUM SHOCK
Operating
Half sine shock in all operational orientations of 31G 5% with a pulse
duration of 2.6 ms 10%
Storage
Half sine shock on all six sides of 71G 5% with a pulse duration of 2 ms
10% Square wave shock on all six sides of 27G with velocity change @
235 in/sec or greater
ALTITUDE
Operating
-16 to 3048 m (-50 to 10,000 ft) Note: For altitudes above 2950 feet, the
maximum operating temperature is de-rated 1°F/550 ft
Storage
-16 to 10,600 m (-50 to 35,000 ft)
E. Power Consumption Testing
FEATURE ENERGY SMART PSU HIGH OUTPUT PSU
Dimensions
L-249 mm
1
x W-65.5 mm x H-38.2 mm
Status Indicators
1 x bi-color Light Emitting Diode
Integrated Fans
None
Fixed Input Plug
IEC-C14
AC Cord Rating
15 Amps @ 120 VAC, 10 Amps @ 240 VAC
Input Voltage
90 – 264 VAC
Auto-ranging
Yes
Line Frequency
47 – 63 Hertz
Maximum Inrush Current
55 Amps per supply for 10 ms or less
Hot-Swap Capability
Yes
Output Power
502 Watts 717 Watts
Maximum Heat Dissipation
1712.9 BTU per hour 2446.5 BTU per hour
Efciency (20% - 100% Load)
86.5 - 90% @ 115 VAC
88 - 92% @ 230 VAC
85 – 88.5% @ 115 VAC
86.5 – 90.5% @ 230 VAC
F. Maximum Input Amps
Maxinputcurrent(HighOutput):10.5A@90VAC,5.3A@180VAC
Maxinputcurrent(EnergySmart):7.0A@90VAC,3.5A@180VAC