Altitude
Note:
Up to 35°C (95°F): Maximum temperature is reduced by
1°C/300 m (1°F/547 ft) above 950 m (3,117 ft).
35°C to 40°C (95°F to 104°F): Maximum temperature is
reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft).
40°C to 45°C (104°F to 113°F): Maximum temperature is
reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft).
Storage Maximum altitude 12,000m (39,370 ft)
Dell R630 server physical specifications
Type Description
Dimensions
Height: 4.28 cm (1.69 inch)
Width: 48.24 cm (18.99 in)
Depth: 70 cm (27.58 in)
Weight (maximum
configuration)
18.6 kg (41 lb)
Dell R630 server temperature and humidity requirements
Specification
Value
Temperature range
Operating (for altitude less
than 950m or 3,117ft)
10° to 35 °C (50° to 95 °F) with no direct sunlight on the equipment.
Storage -40° to 65° C (-40° to 149° F) with a maximum temperature gradation of 20
°C (36 °F) per hour
Relative humidity
Operating 10% to 80% (non-condensing) with 26 °C (78.8 °F) maximum dew point
Non-operating 5% to 95% with 33°C (91 °F) maximum dew point