Figure 110. Installing the battery into the battery holder
7. Tilt the battery holder assembly to align the tabs with the front PERC shroud.
8. Press the battery holder assembly on to the front PERC shroud.
9. Connect the battery power cable to the front PERC card.
NOTE: Route the battery cable into the front PERC shroud cable holder.
Figure 111. Installing the battery holder assembly into the PERC shroud
10. Align the connectors on the front PERC module with the connectors on the drive backplane.
11. Slide the front PERC module until the module is connected to the drive backplane.
12. Using a Phillips #2 screwdriver, tighten the captive screws on the front PERC module.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
144 Installing and removing system components