EasyManua.ls Logo

Dell PowerEdge R6615 9JNDF - Page 101

Dell PowerEdge R6615 9JNDF
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 72. Configuration 4-1: 10 x 2.5-inch SAS4/SATA RAID (with FPERC11)
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 74. 10 x 2.5-inch SAS4/SATA RAID (with FPERC11)
Order From To
1 SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power connector)
2 SL1 (signal connector on system board) CTRL_DST_PA1 (front PERC)
3 CTRL_SRC_SB1 (front PERC) BP_DST_SB1 (backplane signal connector)
Figure 73. Configuration 4-2: 10 x 2.5-inch SAS4/SATA RAID (with FPERC12)
Installing and removing system components
101

Table of Contents

Related product manuals