Figure 70. Configuration 3-2: 8 x 2.5-inch NVMe RAID (with FPERC11 N)
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 72. 8 x 2.5-inch NVMe RAID (with FPERC11 N)
Order From To
1 SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power connector)
2 SL1 (signal connector on system board) CTRL_DST_PA1 (front PERC)
3 CTRL_SRC_SA2 (front PERC) BP_DST_PA1 & BP_DST_PB1 (backplane signal
connector)
4 CTRL_SRC_SB2 (front PERC) BP_DST_PA2 & BP_DST_PB2 (backplane signal
connector)
5 CTRL_DST_PB1 (front PERC) BP_DST_SA1 (front PERC power connector)
Installing and removing system components 99