NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 66. 4 x 3.5-inch SAS3/SATA RAID
Order From To
1 SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power connector)
2 SL1 (signal connector on system board) CTRL_DST_PA1 (front PERC)
NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Figure 50. 8 x 2.5-inch NVMe
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 67. 8 x 2.5-inch NVMe
Order From To
1 SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power connector)
2 SL1 (signal connector on system board) BP_DST_PA1 (backplane signal connector)
3 SL3 (signal connector on system board) BP_DST_PB1 (backplane signal connector)
4 SL7 (signal connector on system board) BP_DST_PA2 (backplane signal connector)
5 SL8 (signal connector on system board) BP_DST_PB2 (backplane signal connector)
Installing and removing system components 85