Figure 74. 8 x 2.5-inch Universal Smart Flow with Front PERC 12
Table 74. 8 x 2.5-inch Universal Smart Flow with Front PERC 12
Order From To
1 SL1_CPU2_PA4 (signal connector on system board) BP_DST_PA1 (backplane signal connector)
2 IO_RISER4 (CPU2) (Riser 1 connector on system
board) )
CTRL_DST_PA1 and CTRL_DST_PB2 (fPERC input
connector)
3 SL3_CPU1_PA1 (signal connector on system board) BP_DST_PB1 (backplane signal connector)
4 SL4_CPU_1_PB1 (signal connector on system board) BP_DST_PA2 (backplane signal connector)
5 SL5_CPU1_PB2 (signal connector on system board) BP_DST_PB2 (backplane signal connector)
6 SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power connector)
7 FPERC_GF (Front PERC power connector) BP_PWR_CTRL (backplane power controller)
8 CTRL_SRC_SA1 (fPERC controller connector) BP_DST_SB1 and BP_DST_SA1 (backplane signal
connector)
Figure 75. 10 x 2.5-inch SAS/SATA with Front PERC 11
Table 75. 10 x 2.5-inch SAS/SATA with Front PERC 11
Order From To
1 SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power connector)
2 CTRL_SRC_SB1 (fPERC controller connector) BP_DST_SB1 (backplane signal connector)
3 SL3_CPU_1_PA1 (signal connector on system board) CTRL_DST_PA1 (fPERC input connector)
Installing and removing system components 101