EasyManua.ls Logo

Dell PowerEdge R730 - Idrac Direct LED Indicator Codes

Dell PowerEdge R730
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Drive-status indicator pattern (RAID only) Condition
Blinks green two times per second Identifying drive or preparing for removal.
Off Drive ready for insertion or removal.
NOTE: The drive status indicator remains off until
all hard drives are initialized after the system is
turned on. Drives are not ready for insertion or
removal during this time.
Blinks green, amber, and turns off Predicted drive failure
Blinks amber four times per second Drive failed
Blinks green slowly Drive rebuilding
Steady green Drive online
Blinks green three seconds, amber three
seconds, and turns off six seconds
Rebuild aborted
iDRAC Direct LED indicator codes
NOTE: The iDRAC Direct LED indicator does not light up for the USB mode.
Figure 9. iDRAC Direct LED indicator
1. iDRAC Direct status indicator
The table below displays iDRAC Direct activity when configuring iDRAC Direct by using the management
port (USB XML Import).
Convention iDRAC Direct
LED indicator
pattern
Condition
A Green Lights green for a minimum of 2 seconds at the beginning and end
of a file transfer.
B Flashing green Indicates file transfer or any operation tasks.
21