54 Dell EMC Networking with Isilon Front-End Deployment and Best Practices Guide | version 1.0
S4048-ON Leaf 3
S4048-ON Leaf 4
interface tengigabitethernet 1/1
description Isilon Node 4-10gige-1
no shutdown
port-channel-protocol LACP
port-channel 1 mode active
mtu 9216
flowcontrol rx on tx off
interface tengigabitethernet 1/3
description Isilon Node 5-10gige-1
no shutdown
port-channel-protocol LACP
port-channel 3 mode active
mtu 9216
flowcontrol rx on tx off
interface tengigabitethernet 1/5
description Isilon Node 6-10gige-1
no shutdown
port-channel-protocol LACP
port-channel 5 mode active
mtu 9216
flowcontrol rx on tx off
interface tengigabitethernet 1/17
description Server 3-1
no shutdown
port-channel-protocol LACP
port-channel 101 mode active
mtu 9216
flowcontrol rx on tx off
interface tengigabitethernet 1/19
description Server 4-1
no shutdown
port-channel-protocol LACP
port-channel 102 mode active
mtu 9216
flowcontrol rx on tx off
interface tengigabitethernet 1/1
description Isilon Node 4-10gige-2
no shutdown
port-channel-protocol LACP
port-channel 1 mode active
mtu 9216
flowcontrol rx on tx off
interface tengigabitethernet 1/3
description Isilon Node 5-10gige-2
no shutdown
port-channel-protocol LACP
port-channel 3 mode active
mtu 9216
flowcontrol rx on tx off
interface tengigabitethernet 1/5
description Isilon Node 6-10gige-2
no shutdown
port-channel-protocol LACP
port-channel 5 mode active
mtu 9216
flowcontrol rx on tx off
interface tengigabitethernet 1/17
description Server 3-2
no shutdown
port-channel-protocol LACP
port-channel 101 mode active
mtu 9216
flowcontrol rx on tx off
interface tengigabitethernet 1/19
description Server 4-2
no shutdown
port-channel-protocol LACP
port-channel 102 mode active
mtu 9216
flowcontrol rx on tx off
Configure the necessary downstream port channels. There will be one port channel for each server as well as
a single port channel for each of the Isilon nodes. Each port channel is assigned an MTU of 9216 to support
jumbo frames. The vlt-peer-lag-port-channel # command ensures that each switch in the VLT is
aware of all port channels and can act accordingly in the event of a switch failure.