Figure 72. 12 x 3.5 SAS/SATA with APERC 11 in Riser 2
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 67. 12 x 3.5 SAS/SATA with APERC 11 in Riser 2
Order From To
1 CTRL_SRC_SB1 (fPERC controller
connector)
BP_DST_SB1 (backplane signal
connector)
2 SIG_PWR_1 (system board power
connector)
BP_PWR_1 (backplane power
connector)
3 CTRL_SRC_SA1 (fPERC controller
connector)
BP_DST_SA1 (backplane signal
connector)
110 Installing and removing system components