PowerEdge T110 II Technical Guide 19
5.4 Environmental Specifications
Table 4 summarizes the environmental specifications for the PowerEdge T110 II.
Environmental Specifications Table 4.
Specification
Operating Requirements
Non-Operating Requirements
Temperature Ranges

10°C to 35°C
(50°F to 95°F)
-40°C to 65°C
(-40°F to 149°F)
Temperature Ranges
(For altitude > 900m or 2952.75ft)
10°C to T
1
°C
(50°F to T
1
°F)
Temperature Gradient
(maximum per 60 minutes)
10°C
20°C
Humidity Percent Ranges
(noncondensing)
20% to 80%
(maximum wet bulb
temperature = 29°C)
5% to 95%
(maximum wet bulb
temperature = 38°C)
Humidity Gradient
(maximum per 60 minutes)
10%
10%
Altitude Ranges
Low Limits
-50ft
(-15.2m)
-50ft
(-15.2m)
High Limits
10,000ft
(3048m)
35,000ft
(10,668m)
Airborne contaminants
ISA-71 Level
G1 
relative humidity. See Table 3 in ISA-71.04-1985.
1
Use the formulas in Table 5 to calculate the maximum operating temperature, T (°C or °F), for the given
altitude (in meters or feet).
Formulas for Maximum Operating Temperature at Given Altitude Table 5.
Temperature
Scale
Formula
Altitude in Meters
Altitude in Feet
Celsius
35

(

)
- 

°C
35

(

)
- 

°C
Fahrenheit
95

(

)
- 

°F
95

(

)
- 

°F

Table of Contents