About Your System 37
System Messages
System messages appear on the screen to notify you of a possible problem
with the system.
NOTE: If you receive a system message not listed in the table, check the
documentation for the application that is running when the message appears or the
operating system's documentation for an explanation of the message and
recommended action.
W1228 RAID
Controller
battery
capacity <
24hr.
Warns predictively that
the RAID battery has less
than 24 hours of charge
left.
Allow RAID battery to
charge to greater than 24
hours of sustained charge.
If problem persists,
replace RAID battery. See
"Installing a RAID
Battery."
W1627 Power required
> PSU wattage.
Check PSU and
config.
The system configuration
requires more power than
what the power supply can
provide.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
W1628 Performance
degraded.
Check PSU and
system
configuration.
The system configuration
requires more power than
what the power supply can
provide, but it can boot if
throttled.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
NOTE: For the full name of an abbreviation or acronym used in this table, see the
"Glossary."
Table 1-1. LCD Status Messages (continued)
Code Text Causes Corrective Actions