EasyManua.ls Logo

Dell PowerEdge XE9680 - Installing a power supply unit

Dell PowerEdge XE9680
221 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1. Follow the safety guidelines listed in the Safety instructions.
2. Disconnect the power cable from the power outlet and from the PSU that you intend to remove.
3. Remove the cable from the strap on the PSU handle.
4. Unlatch and lift or remove the optional cable management accessory if it interferes with the PSU removal.
NOTE: For information about the cable management when the PSU is removed or installed while the system is in a rack,
see the systems cable management arm documentation at PowerEdge Manuals.
Steps
Press the release latch and holding the PSU handle, slide the PSU out of the bay.
Figure 94. Removing a power supply unit
Next steps
1. Replace the PSU.
Installing a power supply unit
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. For systems that support redundant PSU, ensure that all the PSUs are of the same type and have the same maximum output
power.
NOTE: The maximum output power (shown in watts) is listed on the PSU label.
Steps
Slide the PSU into the PSU bay until the release latch snaps into place.
126
Installing and removing system components

Table of Contents