I2C bus
NOTE: After a thermal shutdown, the I2C bus could lock up occasionally. If a lock up occurs, you must manually power cycle
the switch.
Direct attach cables (DACs)
CAUTION: When removing optics with DACs from the port, pull the release tab firmly and steadily. If you have
difficulties pulling out the cable, gently push the optic into the port with one hand while pulling the release tab slightly
upwardstowards the cable/module centerwith the other hand. Do not jerk or tug repeatedly on the tab.
Power cycle the switch
CAUTION: After powering off the switch and before power cycling on the switch back on, be sure that the PSU LED
indicator is offno color displays.
ONIE infrastructure support
This release includes ONIE infrastructure support for firmware updates.
Multiple power cords
The switch has multiple power cords. Before servicing, ensure all power cords are disconnected.
Resolved issues
The following table lists the resolved issues.
Table 5. Resolved issues in this release
PR number Description Severity
BL-728 Fixed the following INTEL-SA-00233
related security vulnerabilities:
CVE-2018-12126
CVE-2018-12127
CVE-2018-12130
CVE-2019-11091
Sev 1
BL-822 The switch reboots when a wrong user
password is entered more than three
times.
Sev 2
Known issues
The following table lists the known issues.
Table 6. Known issues in this release
PR number Description Work around Severity
None -- -- --