Table 9. Additional environmental requirements(continued)
Specification Measurement/description
Back pressure created by rack doors and obstacles not to exceed 5 Pa (~0.5
mm H
2
O).
Altitude, operating
900 m at 45°C
3050 m at 33°C
NOTE: Ramp altitude at 3.81 m/s and Temperature at 20°C/Hr
Altitude, non-operating Maximum 12,000 m (39,370 ft)
Shock, operating 6.0 g, 11 millisecond, four positive and four negative shocks in each of the three
axes, 24 total shocks
Shock, non-operating square shock 25.0 g, 3 millisecond, three positive and three negative shocks in each of the three
axes, 18 total shocks
50.0 g, 2 millisecond, one time/face (except front and rear face), total four pulses
Shock, non-operating half sine shock
Vibration, operating 0.21 G
rms
, 5 Hz500 Hz, X, Y, Z axis, random vibration spectrum: 10 minutes/axis
Vibration, non-operating random chassis 0.47 G
rms
, 4 Hz500 Hz, vertical axis, random vibration spectrum: 90 minutes/axis
0.39 G
rms
, 4 Hz500 Hz, horizontal axis, random vibration spectrum: 30 minutes/
axis
Vibration, non-operating random rack
level
0.88 G
rms
, 2 Hz200 Hz, random vibration spectrum: 15 minutes, only normal
shipping orientation
Vibration, non-operating package
transporting
1.15 G
rms
, 1 Hz200 Hz, 4 product sides (bottom, top, left, right), 30 in/side
Acoustics Operating sound power L
WAd
8.0 Bels (re 1 pW) @ 23 ± 2°C
Orientation and mounting 19" rack mount
Power-on and reset
The firmware boot time from power-on reset or soft reset to SMP target readiness is typically less than two minutes. Actual
boot time may vary depending on your specific configuration.
Power supply unit
Table 10. Power supply unit specifications
Specification Measurement/description
Maximum
output power
1500 W maximum continuous output power at high line voltage
Voltage
High Line AC input voltage, 200-240 V nominal
240 VDC (China only)
Frequency 50/60 Hz
Power factor
correction
95% @ 100% load
Efficiency At 230 VAC input voltage (RMS)
>81% @ 10% load
>90% @ 20% load
>94% @ 50% load
>91% @ 100% load
At 180 VAC input voltage (RMS)
>81% @ 10% load
>89% @ 20% load
>93% @ 50% load
>90% @ 100% load
Technical specifications 45