EasyManua.ls Logo

Dell PowerVault MD3200i - Enterprise Management Window (EMW) Usage

Dell PowerVault MD3200i
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
62 Appendix—Manual Configuration of iSCSI
c
Verify that the following time-out value is set to 30:
node.session.timeo.replacement_timeout = 30
d
Save and close the
/etc/iscsi/iscsid.conf
file.
5
From the console, restart the iSCSI service with the following command:
service iscsi start
6
Verify that the iSCSI service is running during boot using the following
command from the console:
chkconfig iscsi on
7
To display the available iSCSI targets at the specified IP address, use the
following command:
iscsiadm –m discovery –t st -p
<IP_address_of_iSCSI_port>
8
After target discovery, use the following command to manually log in:
iscsiadm -m node –l
This log in is performed automatically at startup if automatic startup is
enabled.
9
Manually log out of the session using the following command:
iscsiadm -m node -T <initiator_username> -p
<target_ip> -u
Step 4: Configure Host Access
This step specifies which host servers access virtual disks on the storage array.
You should perform this step:
• Before mapping virtual disks to host servers
• Any time you connect new host servers to the storage array
1
Launch MDSM.
2
Navigate to the AMW and click
Manually define hosts
.
3
At
Enter host name
, enter the host server for virtual disk mapping.
This can be an informal name, not necessarily a name used to identify the
host server to the network.
4
Select a method for adding the host port identifier.
book.book Page 62 Sunday, September 11, 2011 10:24 PM