200 Script Commands
Set RAID Controller Module
This command defines the attributes for the RAID controller modules.
Syntax
set controller [(0 | 1)]
availability=(online | offline | serviceMode) |
ethernetPort [(1 | 2)]=ethernetPortOptions |
globalNVSRAMByte [nvsramOffset]=
(nvsramByteSetting |
nvsramBitSetting) |
hostNVSRAMByte [hostType, nvsramOffset]=
(nvsramByteSetting |
nvsramBitSetting) |
IPv4GatewayIP=ipAddress |
IPv6RouterAddress=ipv6Address |
iscsiHostPort [(1 | 2 | 3 | 4)]=
iscsiHostPortOptions
rloginEnabled=(TRUE | FALSE) |
serviceAllowedIndicator=(on | off)
Parameters
Parameter Description
controller The RAID controller module for which you want to
define properties. Valid identifiers for the RAID
controller module are 0 or 1, where, 0 is the RAID
controller module in slot 0, and 1 is the RAID
controller module in slot 1. Enclose the identifier
for the RAID controller module in square brackets
([ ]). If you do not specify a RAID controller
module, the firmware for the RAID controller
module returns a syntax error.
availability The mode for the RAID controller module, which
you can set to online, offline, or serviceMode
(service).