EasyManua.ls Logo

Dell PowerVault MD3220 - Synchronizing RAID Controller Module Clocks; Locating Physical Disks

Dell PowerVault MD3220
279 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintaining a Storage Array 95
To determine which virtual disks have reservations, run the following command:
show (allVirtualDisks | virtualDisk
[virtualDiskName] | virtualDisks [virtualDiskName1
... virtualDiskNamen]) reservations
To clear persistent virtual disk reservations, run the following command:
clear (allVirtualDisks |
virtualDisk[virtualDiskName] | virtualDisks
[virtualDiskName1" ... "virtualDiskNamen])
reservations
Synchronizing RAID Controller Module Clocks
To synchronize the clocks on both RAID controller modules in a storage array
with the host clock, run the following command:
set storageArray time
Locating Physical Disks
At times, you might need to locate a specific physical disk. In very large
storage array configurations, this can sometimes be awkward. If you need to
locate a specific physical disk, turn on the indicator LED on the front of the
physical disk. To turn on the indicator LED on a physical disk, run the
following command:
start physicalDisk [enclosureID,slotID] blink
To turn off the indicator LED after locating the physical disk, run the
following command:
stop physicalDisk blink
book.book Page 95 Friday, March 4, 2011 10:45 AM

Table of Contents

Other manuals for Dell PowerVault MD3220

Related product manuals