Troubleshooting 71
Unable to assign the
drive letter to the
snapshot virtual disk.
Unable to access the
snapshot virtual disk.
System Error Log
displays a warning with
event 59 from partmgr
stating that the
snapshot virtual disk is
a redundant path of a
cluster disk.
The snapshot virtual disk
has been erroneously
mapped to the node that
does not own the source
disk.
1
Unmap the snapshot virtual
disk from the node not owning
the source disk.
2
Assign it to the node that owns
the source disk. For more
information, see "Using
Advanced (Premium)
PowerVault Modular Disk
Storage Manager Features" on
page 63.
Table A-1. General Cluster Troubleshooting
(continued)