EasyManua.ls Logo

Dell PowerVault MD3600i - Page 64

Dell PowerVault MD3600i
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
64 Appendix—Manual Configuration of iSCSI
If you plan to configure CHAP authentication, do not perform discovery on
more than one iSCSI port at this point. Go to "Step 4: Configure Host
Access" on page 65.
If you do not plan to configure CHAP authentication, repeat step 1 thorough
step 6 for all iSCSI ports on the storage array.
If you are using Windows Server 2008 Core Version:
1
Set the iSCSI initiator service to start automatically:
sc \\<server_name> config msiscsi start=auto
2
Start the iSCSI service:
sc start msiscsi
3
Add a target portal:
iscsicli QAddTargetPortal
<IP_address_of_iSCSI_port_on_storage array>
If you are using Red Hat Enterprise Linux 5, Red Hat Enterprise Linux 6,
SUSE Linux Enterprise Server 10, or SUSE Linux Enterprise Server 11:
Configuration of the iSCSI initiator for Red Hat Enterprise Linux 5 and
SUSE Linux Enterprise Server 10 SP1 distributions is done by modifying the
/etc/iscsi/iscsid.conf file, which is installed by default when you install
MDSM. You can edit the file directly, or replace the default file with a sample
file included on the PowerVault MD3600i Series resource media.
To use the sample file included on the media:
1
Make a copy of the default
/etc/iscsi/iscsid.conf
file by saving it to another
directory of your choice.
2
Edit the following entries in the
/etc/iscsi/iscsid.conf
file:
a
Edit or verify that the
node.startup = manual
line is disabled.
b
Edit or verify that the
node.startup = automatic
line is
enabled. This enables automatic startup of the service at boot time.
c
Verify that the following time-out value is set to 30:
node.session.timeo.replacement_timeout = 30
d
Save and close the
/etc/iscsi/iscsid.conf
file.
3
From the console, restart the iSCSI service with the following command:
service iscsi start
book.book Page 64 Wednesday, December 29, 2010 9:23 PM

Table of Contents

Other manuals for Dell PowerVault MD3600i