Table 50. Rugged specific testing (continued)
Test Name Test procedure Semi-Rugged
s
pecifications
Fully-Rugged
specifications
9
0 minutes per axis 90 minutes per axis
Operational test
Cold boot test Custom - Cold Boot
C
old soak for 8 hours (unit
off), One cycle
Cold soak for 8 hours
at varying temperatures
(-18°C, -20°C, -23°C,
-29°C)
System boot: Remove
system from cold
environment and begin
boot process immediately.
Cold soak for 8 hours (unit
off), One cycle
Cold soak for 8 hours
at varying temperatures
(-18°C, -20°C, -23°C,
-29°C)
System boot: Remove
system from cold
environment and begin
boot process immediately.
Dust ingress protection IEC 60529, IP-Xx IP-5x
C
omplete protection
against contact
Non-operating
IP-6x
No ingress of dust
Complete protection
against contact
Non-operating
Thermal and acoustic improvements
T
he following table lists the thermal and acoustic improvements of your Precision 5480.
Table 51. Thermal and acoustic improvements
100% dual heat pipe Increase the heat capacity to improve thermal dissipation
Better system tuning/setting Get higher performance and good user experience
Pro-OS enhanced thermal setting (Dynamic PL1) Increases boot-up time
Linear fan control Fan speed ramp more smoothly for better user experience, no
m
ore significant acoustic changing
DDT SSD setting Protecting the SSD device in high temperature and worse
cases to prevent blue screen of death (BSOD)
IEC 60529 ingress protection: IP-54
D
ust protected
Protected against dripping water
Better acoustic experience Enhance acoustic to 0.6 sone during daily working conditions
a
nd fan off when system is idle
System management features
D
ell commercial systems come with a number of systems management options that are include by default for In-Band
management with our Dell Client Command Suite. In-Band management meaning that the Operating System is functional and
the device is connected to a network so that it can be managed. The Dell Client Command Suite of tools can be leveraged
individually or with a systems management console like SCCM, LANDESK, KACE, etc.
We also offer Out-of-Band management as an option. Out-of-band management is when the system does not have a functional
operating system or is turned off and you still want to be able to manage the system in that state.