EasyManua.ls Logo

Dell XPS 15 - Replacing the Heat-Sink Assembly; Procedure

Dell XPS 15
117 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Identifier GUID-9847FD24-88EC-4F5A-BCCF-D9D9830B777A
Status Released
Replacing the heat-sink assembly
WARNING: Before working inside your computer, read the safety
information that shipped with your computer and follow the steps in Before
working inside your computer. After working inside your computer, follow
the instructions in After working inside your computer. For more safety best
practices, see the Regulatory Compliance home page at www.dell.com/
regulatory_compliance.
CAUTION: Incorrect alignment of the heat sink can damage the system
board and processor.
NOTE: The original thermal grease can be reused if the original system
board and fan are reinstalled together. If either the system board or the fan
is replaced, use the thermal pad provided in the kit to ensure that thermal
conductivity is achieved.
Identifier GUID-6735D332-2AE0-440D-9A7D-54D6D917B52A
Status Released
Procedure
1 Align the screw holes on the heat-sink assembly with the screw holes on the
system board.
2 Replace the ve screws (M2x3) that secure the heat-sink assembly to the
system board.
NOTE: Depending on the conguration ordered, some congurations
may have four screws (M2x3).