EasyManua.ls Logo

Delta Electronics EXIO14RAE - Page 117

Delta Electronics EXIO14RAE
157 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix D Use of Application Instructions|DOP-EXIO Series
D-36
Revision March, 2008, Doc. Name: 2007PDD23000014
Program Example 1:
When X0 = On, D0 will be divided by D10 and the quotient will be stored in D20 and remainder in D21.
On/Off of the highest bit indicates the positive/negative status of the result value.
X0
DIV D0 D10 D20
D0 D10 K4Y0
DIV
Program Example 2:
When X0 = On, (D1, D0) will be divided by (D11, D10) and the quotient will be stored in (D21, D20) and
remainder in (D23, D22). On/Off of the highest bit indicates the positive/negative status of the result
value.
X0
DDIV D0 D10 D20
D0 D10 K8Y0
DDIV