Chapter 6 Applied Instructions
6-18
Comparison symbol
Comparison operation result
$
OFF
$<=
OFF
Example:
When the string starting with the data in D0 is equal to the string staring with D2, Y0.0 is ON.
Additional remark:
1. If the string does not end with 16#00, the instruction is not executed, SM is ON, and the error
code in SR0 is 16#200E.