Chapter 8 ParametersASDA-A2R Series
Revision December, 2014
8-99
Unit
pulse
Range
1 ~ 128000000
Data Size
32bit
Format
DEC
Settings
The setting of excessive position control deviation warning in
servo drive error display (P0-01)
P2-36 EDI9 Extended EDI9 Functional Planning
Address: 0248H
0249H
Operational
Interface
Panel / Software Communication
Related Section:
Table 8.1
Default
0
Control
Mode
ALL
Unit
-
Range
0 ~ 0x015F (the last two codes are EDI
code)
Data Size
16bit
Format
HEX
Settings
Input function selection: Please refer to table 8.1
Input contact: a or b contact
0: Set the input contact as normally closed (b contact)
1: Set the input contact as normally opened (a contact)
(P2-36 ~ P2-41) The setting value of function programmed
When parameters are modified, please re-start the servo drive to
ensure it can work normally.
P2-37 EDI10 Extended EDI10 Functional Planning
Address: 024AH
024BH
Operational
Interface
Panel / Software Communication
Related Section:
Table 8.1
Default
0
Control
Mode
ALL
Input function selection
Input contact
Not in use