DVP-15MC Series Motion Controller Operation Manual
11-366
2. Motion Curve and Timing Chart of the terminal actuator
Y a xis
100000
X axis
LINREL1
250000
LINREL1_Ex
LINREL1_Abt
LINREL1_Done
LINREL1_Err
LINREL1_Bsy
LINREL1_Act
LINREL2_Abt
LINREL2_Done
LINREL2_Err
LINREL2_Bsy
LINREL2_Act
LINREL2
0 0
A
100000
B
C
D
Set BufferMode to mcBlendingPrevious, TransitionMode to mcTMCornerDistance and
TransitionParameter to 10000 for LINREL2.
LINREL1_Dis [1] and LINREL1_Dis [2] of LINREL1 are both set to 100,000. LINREL2_Dis [1] and
LINREL2_Dis [2] of LINREL2 are set 150,000 and 0.
ADDAXIS1 and ADDAXIS2 are executed first and then DMC_GroupEnable0 is executed. When the
axes group is enabled, LINREL1 is excecuted and then LINREL2 is executed immediately.
When the terminal actuator gets to point B in the coordinate system, LINREL1_Done changes to
TRUE. Meanwhile LINREL2_Act changes to TRUE and LINREL2 starts to execute.
After LINREL2 is executed, the terminal actuator moves along an arc and then continues to make
the linear interpolation after passing by point C.
The distance from point B to point A equals that from point C to point A. It is also equal to 10,000, the
value of TransitionParameter of LINREL2.