Chapter 8 TroubleshootingVP3000
484
ID No.
Warning Name
Descriptions
162
Controller calculation
overload
(MCOL)
Controller calculation is overload
Action and Reset
Action Condition
Warning occurs when the controller calculation is more than 85%
Action Time
Immediately displayed
Warning Setting Parameter
N/A
Reset Method
Auto-reset
Reset Condition
Controller calculation is lower than 80%
Record
No
Cause
Corrective Actions
Controller calculation is overload
Decrease the carrier frequency of Pr. A5-00.