8
electrical connections
Electrical wiring must be installed by a qualified
professional technician.
An Idm<30 mA residual current device and a safety
device against overcurrent, corresponding to the
connection line characteristics, must be used to pro-
tect the power supply to the towel heater, in conform-
ity to standards in force.
Make sure the mains voltage effectively corresponds
to the one shown on the appliance, before use.
This towel heater is fitted with class 1 immersion
heating element in water and glycol and must be
earthed.
The three cables must be coupled up in a terminal
box conforming to standards in force, or by using a
Schuko plug.
Single phase power supply 230 V~ 50Hz:
- Blue wire: Neutral
- Brown wire: Phase
- Green and yellow wire: Earth lead
range and dimensions
Width
Depth
Height
500 mm minimum
Models Power Height Width Depth Nr. of tubes
FSE045EC 150 W 450 mm 500 mm 110 mm 8
FSE070EC 300 W 700 mm 500 mm 110 mm 13