2.4. Procedure
(1) Adjust the signal of S MONITOR OUT by the wave of os-
cilloscope.
(a) Target, Y-signal
Point : 1U-3645-2 VR802
Adjustment Value : 714 ± 14mV
Waveform
(b) Target, C-signal
Point : 1U-3645-2 VR803
Adjustment Value : 286 ± 5mV
Waveform
(2) Adjust the signal of COMPONENT OUT by the wave of
oscilloscope.
(a) Target, Y-signal
Point : 1U-3645-2 VR702
Adjustment Value : 714 ± 14mV
Waveform
(b) Target, P
B/CB-signal
Point : 1U-3645-2 VR703
Adjustment Value : *525 ± 10mV
Waveform
Y-signal of S MONITOR OUT
Y
C
C-signal of S-MONITOR
Y
Y-signal COMPONENT OUT
PB/CB-signal COMPONENT OUT
PB/CB
2.4. 手順
(1) セットの SMONITOROUT の信号レベルをオシロスコー
プ上の波高値で調整します。
(a) Y 信号レベル
調整個所 1U-3645-2VR802
調整値 714 ± 14mV
波形
(b) C 信号レベル
調整個所 1U-3645-2VR803
調整値 286 ± 5mV
波形
(2) COMPONENTOUTの信号レベルをオシロスコープ上の
波高値で調整します。
(a) Y 信号レベル
調整個所 1U-3645-2VR702
調整値 714 ± 14mV
波形
(b) P
B/CB 信号レベル
調整個所 1U-3645-2VR703
調整値 525 ± 10mV
波形
SMONITOROUT Y 信号レベル
Y
C
SMONITOR C 信号レベル
Y
COMPONENTOUT Y 信号レベル
PB/CB
COMPONENTOUT PB/CB 信号レベル