39
CH SEL
ENTER
(Main unit) (Remote control unit)
5
When “Store” is selected, all parameters are stored
up.
After the data is stored, the “Auto Setup / Room EQ”
menu screen appears automatically.
NOTE:
Do not turn off the power while the data is
being stored. If the power is turned off while
the data is being stored, the Room EQ
parameters stored in the memory will be
cleared, and it will not be possible to select the
“Audyssey”, “Front” or “Flat” equalizer
settings.
About the error message
These error messages will be displayed when performing the measurements of Auto Setup and the automatic measurements can not be
completed because of the speaker arrangement, measurement environment, or other factors. Please check the following matters, reset the
pertinent items, and measure again. Be sure to turn off the AVC-A1XV’s power before checking the speaker connections.
Screen example Cause Measures
The speakers required for producing suitable
reproduction have not been detected.
q The front L and front R speakers were not properly
detected.
w Only one channel of the surround (A) and surround
(B) speakers was detected.
e Sound was output from the R channel when only
one surround back speaker was connected.
r The surround back or the surround (B) speaker
was detected, but the surround (A) speaker was
not detected.
If multiple errors occur, use the cursor left and right
buttons to check the contents.
Check that the pertinent speakers are
properly connected.
The speaker polarity is connected in reverse.
If multiple errors occur, use the cursor left and right
buttons to check the contents.
Check the polarity of the pertinent
speakers.
For some speakers, the screen below
may be displayed even though the
speakers are properly connected.
If so, select “Skip0”.
There is too much ambient noise in the room and the
measurements cannot be made accurately.
Either turn off the power of the
device that generated the noise
during the measurements or move
the device away.
•Try again at a time when it is quieter.
The measurement microphone is not connected, or
all of speakers have not been detected.
Connect the measurement microphone
to the microphone connector.
Check the speaker connection.