Adjusting Idling Current
NOTEAdjusting the idling current when "ECO Mode" is set may damage the Power AMP.
1. Preparation
(1) Prepare a DC voltmeter.
(2) Place the unit under normal usage conditions, away from highly ventilated areas such as next to an
air conditioning machine or electric fan.
The set requires an ambient temperature of 15℃ to 30℃ and standard humidity.
(3) Settings of This Unit
POWER (Power source switch) STANDBY
SPEAKER (Speaker terminal) No load
(Do not connect equipment such as speakers or dummy resistors.)
2. Adjustment Procedure
(1) Make sure that "ECO Mode" is off.
Press the "
SETUP
" button on the remote control to display the GUI menu.
Press the cursor button to select "General" → "ECO" → "Mode" → "Off".
(2) Remove the top cover and turn VR510 (ALL Channel) of the MAIN PCB counterclockwise(
c
) as far as
possible.
(3) Connect the DC Voltmeter to the test points.
FRONT-Lch : CN510 : VR510
FRONT-Rch : CN520 : VR520
(4) Connect the power cord to an outlet. Next, press the power button to turn on the power.
(5) Set this unit as follows.
MASTER VOLUME : "---" (
c
min.) : turn counterclockwise to the lowest position.
SPEAKER (Speaker terminal) : No load
(Do not connect equipment such as speakers or dummy resistors.)
MODE : DIRECT
FUNCTION : TUNER
(6)
E3 model
Turn VR510 clockwise (
x
) and adjust the voltage of the test point to "
4.0mV ± 0.5mV DC
" within 2
minutes.
E2 model
Turn VR510 clockwise (
x
) and adjust the voltage of the test point to "
8.0mV ± 0.5mV DC
" within 2
minutes.
(7)
E3 model
Check whether the voltage is within the range "
4.0mV ±1mV DC
" 10 minutes after adjustment.
E2 model
Check whether the voltage is within the range "
8.0mV ±2mV DC
" 10 minutes after adjustment.
(8) Adjust the variable resistance of each channel using the same method.
E B
B E
2SD2390
KTC3964
B
E
BE
VR510
2SB1560
BE
Q5106
B E
~ ~
+
-
2SD2390
BE
B E
KTC3964
2SB1560
E
B
BE
BEB E
VR520
FRFL
1.HP_LCH
2.AGND
3.HP_RCH
BN505
CN510
CN520
F Rch F Lch
VR560
DC Voltmeter
AMP UNIT