PMA-1315R
METHOD
OF
ADJUSTMENTS
DC
Volimeter
POWER
TRANSFORMER
VR201
IDLING
CURRENT
e
Setup
i
1.
Lay
the
unit
at
an
ordinary
position
away
from
a
direct
current
from
a
cooler
or
fan.
Do
the
adjustment
at
a
temperature
between
15°C
(59°F}
and
30°C
(86°F).
2.
Set
controls
as
follows.
POWER
SWITCH->
OFF
(HL)
VOLUME
CONTROL-
fully
counterclockwise.
(C>
)
min.
(Main
volurne
(VR201)
|
-
(VR202,
203
and 204
are
center
position.)
SPEAKER
Terminals—
open:
do
not
connect
the
speakers,
dummy
load
ete.
@
Confirm
1.
Remove
Top
cover.
And
then
connect
DC
Voltmeter
to
Test
points
of
Main
Unit.
2.
Connect
Power
card
to
AC
Outlet,
and
tum
POWER
Switch
"on"
(2m).
3.
10
seconds
after
check
to
see
DC
Voltmeter
reading
is
17
+
2mvV.
4.
2
minutes
after
re-check
DC
Voltmeter
for
17
+
2mV
reading.