Denon PMA-510 - Denon PMA-510 Adjustment Procedures; Tone & Power Amp Idle Current Adjustment; Equalizer Circuit Adjustment

Denon PMA-510
14 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mm
PMA-510
METHOD
OF
ADJUSTMENT
OC
VOLTMETER
DIGITAL
VOLTMETER
ETC-375
AUE-009B
IDLE
CURRENT
ADJUSTMENT
METHOD
OF
TONE
&
POWER
AMP
(ETC-375
PRINTED
BOARD)
1.
6.
1s
Place
the
unit
in
normal
position,
not
sideways
or
tilted.
Avoid
too
much
ventilation,
since
the
adjustment
must
be
done
where
temperature
is
between
15°C
and
30°C.
Set
the
switches
on
the
unit
as
follows:
Power
>
OFF
Volume
>
—odB
|
Speaker
terminals
No
load
(no
speaker
connected)
Remove
the
top
cover,
and
the
VR7,8,9
and
10
of
the
tone
&
power
amp
printed
board
(2220609001)
fully
counter
clockwise.
.
Connect
a
DC
voltmeter
to
the
test
points
12(+),
13(—)
or
to
22(+),
23(—).
Plug
in
the
AC
cord
to
power
outlet
of:
Europe
220
V
(198~231
V);
U.K.
and
Australia
240
V
(216~252
V};
Canada
and
U.S.A.
120
V
(180~126
V};
and
turn
the
power
on.
immediately
(within
one
minute),
turn
VR7
and
VR8
clockwise
and
adjust
the
test
point
voltage
(VTP)
to
641
mV
preliminarily.
After
about
two
or
three
minutes
of
the
above
preliminary
adjustment,
adjust
VR7
and
VR8
so
as
VTP
reads
641
mV.
Adjust
VRQ
and
VR10
so
as
VTP
reads
1542
mV
preliminarily.
About
4
minutes
after
the
above
preliminary
adjustment,
adjust
VR9
and
VR10
so
as
VTP
reads
2342
mV.
°
ADJUSTMENT
OF
EQUALIZER
(AUE-009B
PRINTED
BOARD)
1.
Insert
short
pins
into
PHONO
input
terminals.
Connect
a
digital
voltmeter
(0.01
mV
~
1
mV
DC
range
must
be
measurable)
into
each
of
REC.
out
terminals
(L
&
R
channels).
For
easier
measuring
to
avoid
value
fluctuation
on
the
meter,
connect
a
100
k
ohm
(1/4W)
resistor
between
the
ends
of
the
R17/18
10
M
ohms
(1/4W)
resistor
on
the
printed
board.
Set
the
FUNCTION
switch
to
“MM”
position,
and
turn
the
main
volume
to
MIN.