Denon UCD-250 - UNIT MECHANISM SERVICE PROCEDURES; Unit Mechanism Removal and Servicing; Lens and Laser Inspection

Denon UCD-250
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
2,
(1)
1)
2)
M2
x
3
binding
screw
(Tightening
torque:
Removal
of
the
unit
mechanism
(Fig.
7)
After
removing
the
loading
mechanism,
remove
the
tab
of
the
bottom
surface
(in
one
location)
as
illustrated
in
Fig.
7.
©3
mm
dia.
x
16
CT
binding
screw
SY
Unit
mechanism
Fig.
7
To
replace
the
DC
motor
(D2)
and
the
turntable,
follow
the
procedure
below
.
Pull
the
turntable
(plastic)
off
vertically
from
the
unit
plate.
When
fitting
on
the
servicing
turntable
(metal),
make
a
height
adjustment.
(Fig.
8)
Do
not
exert
excessive
force
to
the
shaft
of
the
DC
motor
(D2)
at
this
time.
Set
screw
with
hexagonal
hole
(3
mm
dia.)
4
to
6kg)
25.4
4
to
6kg)
For
the
dimensions
at
parts
marked
“2X”,
adjust
the
height
using
the
turntable
height
JIG.
JIG
No.:
SGK-0030
Fig.
8
3)
At
the
time
of
service
replacement
of
the
DC
motor
(D2),
do
not
apply
excessive
force
in
direction
B.
When
part
C
of
the
unit
plate
is
misshapen,
it
will
cause
eye
pattern
deterioration.
(Fig.
9)
Part
C
Direction
B
$
$
Part
C
Unit
plate
(Tightening
torque:
NOTE:
e@
Motor
replacement
or
turntable
replacement
method
Remove
the
pressure-fitted
turntable,
and
remove
the
motor
screws.
e@
Do
not
reuse
a
turntable
(plastic)
that
has
been
removed
once.
(2)
When
disassembling
and
assembling
the
unit
mechanism,
assemble
with
wiring
resembling
that
of
Fig.
10
Inspection
of
the
objective
lens
(Fig.
11)
Handle
so
as
not
to
get
dirt
or
dust
on
the
objective
lens
of
the
lens
actuator
section.
Note
that
when
used
for
a
long
period,
dirt
or
dust
may
have
adhered
to
the
objective
lens.
Try
cleaning
the
surface
of
the
objective
lens
with
a
dry,
clean
cotton
swab.
If
the
dirt
still
does
not
come
off,
moisten
the
cotton
swab
with
a
small
amount
of
water
and
wipe.
When
doing
this,
be
careful
not
to
get
water
on
any
parts
other
than
the
lens.
af:
{
Dise
turntable
Lens
actuator
section
Objective
lens
Fig.
11
Inspection
for
laser
breakdown
The
laser
is
normally
driven
with
a
current
of
30
to
80
mA.
If
this
laser
drive
current
value
is
measured
at
120
mA
or
higher
in
the
circuit,
the
laser
may
be
thought
to
be
faulty.
(The
current
value
is
measured
by
taking
the
voltage
(0.99
to
3.3
V)
across
both
ends
of
R401,
which
is
33
ohms).
5.
(1)
(2)
Precautions
at
time
of
servicing
(Fig.
12)
Semiconductor
laser
The
semiconductor
laser
is
very
susceptible
to
static
electricity
destruction
and
surge
currents.
Be
careful
never
to
touch
the
terminals
of
the
semiconductor
laser
and
the
terminals
of
the
flexible
board
with
your
hands
or
a
tool.
As
illustrated
in
Fig.
12,
the
current
and
light
intensity
character-
istics
increase
abruptly
once
the
threshold
current
value
is
exceeded.
Also
note
that
this
threshold
current
differs
a
little
from
laser
to
laser.
In
view
of
this,
when
replacing
the
unit
mechanism
or
any
work
that
involves
setting
the
amount
of
light
of
the
laser,
be
sure
to
turn
the
adjustment
control
VR401
fully
in
the
counterclockwise
direction,
and
then
raise
it
to
the
specified
value.
Intensity
used
Light
intensity
—=
—=
Current
Threshold
current
value
Fig.
12
Handing
the
unit
mechanism
(Fig.
13)
When
handling
the
pickup
mechanism
and
the
unit
mechanism,
use
a
ground
ring
such
as
the
one
illustrated
in
Fig.
13.(A
ground
ring
can
be
constructed
using
ordinary
lead
wire.)
Ground
ring
(lead
wire)
Connect
to
pickup
case
Resistor
of
1
to
10
Mohms
14
Fig.
13
Connect
to
chassis
(Ground)
6.
D-250
a
CD
PLAYER
SECTION
Inspection
of
the
actuator
(Fig.
14)
Check
the
resistance
value
of
the
actuator
coil.
It
is
normal
if
the
values
are
as
follows:
Focusing
coil
Tracking
coil
If
the
coils
are
open
or
shorted,
the
actuator
may
be
thought
to
be
broken.
Also,
a
1.5
V
battery
can
be
used
to
observe
if
the
lens
moves.
AF
direction
Fig.
14

Other manuals for Denon UCD-250