EasyManua.ls Logo

Denon UCD-250 - OFFSET ADJUSTMENT PROCEDURES; Tracking Offset Adjustment; Focus Offset Adjustment

Denon UCD-250
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
(3)
Tracking
offset
adjustment
Wiring
Diagram
Oscilloscope
(DC
range)
ere
29
IVR6O!
VR6EO2
MAIN
UNIT
1U-2478-1
FRONT
PANEL
SIDE
Adjustment
location
(Control)
Check
items
DC
Voltmenter
Oscilloscope
Adjustment
procedure
1.
|
OPEN/CLOSE
|
Press
the
OPEN/CLOSE
button
and
place
an
adjustment
disc
in
the
disc
holder.
2.|
“OPEN/CLOSE
|
Press
the
OPEN/CLOSE
button
again
and
close
the
disc
holder.
3.|
®
PLAY
|
Press
the
PLAY
button
and
check
that
the
display
indicates
“O2
”.
4.
Short
circuit
the
(+)
and
(—)
terminals
of
the
oscilloscope
and
check
the
board
wiring.
5.
Adjust
the
VR501
“T-OFFSET”
control
and
set
the
upper
and
lower
amplitude
of
the
waveform
to
be
equal.
D-250
CD
PLAYER
SECTION
(4)
Focus
offset
Adjustment
Wiring
diagram
YRGO!I
VREO2
Oscilloscope
MAIN
UNIT
Oscilloscope
1U-2478-1
(or
Digital
Voltmeter)
(Input
impedance
:
more
than
1Mohm)
VR502
Side
terminal
(FEO)
FRONT
PANEL
SIDE
Adjustment
;
location
Check
items
50mV/div
or
20mV/div
Adjustment
Procedure
1.
Press
the
|
BESTOP
|
button.
2.
Adjust
VR502
“F.
OFFSET”
and
set
the
FEO
voltage
to
+70
mV
(+10
mV).
65