DENSITY 390 - Connection diagram examples (PANIC FUNCTION)

DENSITY 390
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.3. Connection diagram examples
(PANIC FUNCTION)
COM 3COM 2COM 1
W3
NO
NC
W4
NO
NC
W5
NO
NC
W6
NO
NC
W7
NO
NC
USB
C PLUS PCB
W2
N
L
FIRETIME
ACTION DAYTIME
PANIC BUTTON FUNCTION
ACTION NIGHTTIME
INTRUDER SYSTEM DISARMED
FOG GENERATOR DISARMED
BUTTON NOT ACTIVATED
FOG GENERATOR ACT LIKE
NORMAL INSTALLATION
BUTTON ACTIVATED
FOG GENERATOR SHOOT
RESET
0V
ARM
PRIMARY TRIG
+ 12V
DIPSWITCH 6 MUST BE ON,
TO ENABLE NC (Normal Closed) ACTION
MAINS
FUSE
F4
INTRUDER SYSTEM ARMED
FOG GENERATOR ARMED
INTRUDER SYSTEM IN ALARM
FOG GENERATOR ARMED
FOG GENERATOR READY TO SHOOT
0V
ARM
PRIMARY TRIG
+ 12V
0V
ARM
PRIMARY TRIG
+ 12V
1
2
3
4
6
5
7
12V OUTINPUTOUTPUTPIR
+ 12V
GND
ARM +
ARM -
TRG +
TRG -
IN 0 +
IN 0 -
IN 1 +
IN 1 -
EMPC
EMP
FLTC
FLT
TMPC
TMP
FVLC
FVL
AUXC
AUX
ACTION ALARM
BOOT
INTRUDER SYSTEM IN ALARM
FOG GENERATOR ARMED
VERIFICATION PIR SIGNAL ACTIVE
FOG GENERATOR SHOOTING FOG
0V
ARM
PRIMARY TRIG
+ 12V
ACTION ALARM + VERIFICATION
0V
+ 12V
PIR SENSOR
STATUS NOT ACTIVATED
PIR SENSOR
STATUS ACTIVATED
PIR +
PIR -
PIRC
0V
+ 12V
W1
IMPORTANT!
JUMPER W1 MUST BE INSERTED
FOR ENABLING PIR FUNCTION
8
IMPORTANT!
DIPSWITCH 8 MUST BE OFF TO
ENABLE NORMAL OPERATION MODE
The PANIC input can be used for immediate shooting.
The machine needs to be HOT and READY (Green light on
and steady).
The PANIC input will overrule the ARM and the SHOOT input.
Shooting time: As Shooting table.
page 11/20