11. Front LED’s
12. Errors
BOOT
USB
W2
W1
FIRETIME
RESET
1 heat exchanger overtemperature
2 temperature regulation fault
3 thermocouple reference fault
4 triac overtemperature
5 thermocouple error
6 eeprom error
7 missing battery
8 low battery voltage
9 main power supply missing
10 main power supply low
11 pump overcurrent
12 pump shortcircuit
13 empty fog rell
To READ out the error present:
PUSH and RELEASE the “RESET” button. Count the number of ashes on the red LED (The BEEPER will also
beep synchronously with the LED’s).
The number counted is the current ERROR of this machine.
NOTICE:
Red STEADY light = The fog rell is EMPTY or on the reserve. Or another error is present (see the list above).
See how to read
an error.
When on: the machine is armed and, if hot, it’s ready to shoot.
ARM
FAULT
HEATING
When on: something is wrong. (See section 12. Errors below)
When on: the machine is hot and ready for the fog emission.
When ashing: the heating process is in progress. In this step, the Density machine is
heating but is not ready to shoot.
Blue LED
Red LED
Green LED
page 17/20
www.densityglobal.com | help@densityglobal.com
Version 1.1.4