Specifications
Power Supply 9V Alkaline Battery
Operating Temperature 32°F to 104°F (0 to 40°C)
Test Limits 750 kilohms to 10 megohms
Test Accuracy ±10% @ 750 kilohms
±15% @ 10 megohms
Test Voltage 4 VDC
Dimensions 3.6" x 2.6" x 1.1"
(91 mm x 66 mm x 28 mm)
Weight 4 oz (113 g)
Limited Warranty, Warranty Exclusions, Limit
of Liability and RMA Request Instructions
See the Desco Warranty -
Figure 2. Using the Portable Wrist Strap Tester and
recording its results
Calibration
The Desco Portable Wrist Strap Tester is calibrated
to NIST traceable standards. There are no user
adjustments necessary. We recommend that calibration
be performed annually using the Desco 07010
Calibration Unit. It is a convenient product which allows
the customer to perform NIST traceable calibration
on single-wire personnel testers. The Calibration
Unit is designed to be used on the shop floor at the
workstation, virtually eliminating downtime, verifying that
the continuous monitor is operating within tolerances.
View technical bulletin TB-2039 for more information.