8) Duress PIN Operation (V3.03)
When using the Duress PIN to disarm a partition when in single partition
mode on a master keypad, the user is able to toggle through all
partitions using # - #.
Any outputs configured to follow Panic/Duress events remain on until a
valid PIN + OFF sequence is issued by a user with at least General
Authority.
9) ARDIS Acknowledgment Wait Time (V3.02)
In response to an ARDIS requirement, the time the panel waits for an
acknowledge signal from ARDIS was increased from 30 to 45 seconds.