NOTE: Take note of the positions and locations of parts during
disassembly to make reassembly easier.
NOTE: Any service operations not included in this section should be
performed by a D
eWALT factory service center or a DeWALTauthorized
service center.
The following procedures must be followed when maintenance or ser-
vice is performed on the generator.

Procedure
Daily
50 hours
or weekly
(whichever
comes first)
100 hours
150 hours or
monthly
(whichever
comes first)
500 Hours
Test GFCI
X
Clean generator’s exterior
X
Clean battery pack and
charger
X
Check oil level+
X
Change oil *+
X(1)
Clean air filter +
X(1)
Clean spark plugs+
X
Check fuel line, hose clamps
and fuel tank
X
Oil leak inspection
X
Spark arrestor
X
Sediment cup
X
Clean fuel tank and filter
X(2)
Check for unusual
noise/vibration
X
Prepare unit for Storage
Prepare unit for storage if it is to remain
idle for more then 30 days
* The engine oil must be changed after the first 20 hours or operation.
Thereafter change oil every 150 hours of operation or monthly, whichever
comes first.
+ See
engine's instruction manual
for correct procedure.
(1) Perform more frequently in dusty or humid conditions
(2)
Should be performed by a DeWALT factory service center or a
D
eWALTauthorizedservicecenter.

TEST GFCI
1. Start the generator. IMPORTANT: Engine must be running to test
GFCI.
2. Place the auto control idle switch (Y) in the OFF
B
A
position.
3. Push in the TEST button A on the receptacle. The
RESET button B will pop out. Power is now off at
the receptacle. If the RESET button does not pop
out, contact a D
eWALT factory service center or
a D
eWALT authorizedservice center. Do not run
generator until the problem can be corrected.
4. To restore power to receptacle, push the RESET
button in. If the RESET button pops out during operation, stop the
generator and check the generator and equipment for defects.
Contact a D
eWALT factory service center or a DeWALTauthorized
service center.

Table of Contents