66
If the difference between the markings is 3 mm or less, the tool is
properly calibrated.
If the difference between the markings is more than 3 mm, the tool must
be serviced.
LEVEL CHECK (FIG. I1, I2)
Place the tool in an area with a wall of at least 9 m length. Mount the
tool to one end of the wall.
Position the tool at an angle of 90° to the left.
Switch on the horizontal laser beam.
Mark the centre of the laser beam at one-third distance (32) and at two-
third distance (33) on the wall.
Switch off the tool.
Mount the tool to the other end of the wall.
Position the tool at an angle of 90° to the right.
Switch on the horizontal laser beam.
Switch on the tool, align the laser beam with the wall marking (33) and
mark the laser beam at two-third distance (34) on the wall.
Switch off the tool.
Measure the difference between the markings (32, 34).
If the difference between the markings is 6 mm or less, the tool is
properly calibrated.
If the difference between the markings is more than 6 mm, the tool must
be serviced.
PLUMB CHECK (FIG. J1, J2)
Place the tool on the floor in an area with a ceiling of at least 2.5 m
height.
Mark a line of 1.5 m length (35) on the floor. Position the tool at one end
of the floor marking (35).
Switch on the vertical laser beam.
Align the laser beam with the floor marking (35).