EasyManua.ls Logo

DeWalt DW089LG - Laser Operation and Accuracy Checks; Turning the Laser On; Horizontal Beam Scan Accuracy

DeWalt DW089LG
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
E
Turning the Laser On
Place the laser on a at level surface. Slide the Power/
Transport Lock switch
F
2
to the right to unlock/turn
ON the laser.
Each laser line is powered on by pressing its button on
the keypad (Figure
F
3
). Pressing the button again
turns the laser line off. The laser lines can be powered
one at a time or all at the same time.
Laser Buttons
DW089LR/LG
Horizontal laser line
(Figure
F
4
)
Side vertical laser line
(Figure
F
5
)
Front vertical laser line
(Figure
F
6
)
DW0811LR/LG Horizontal laser line
(Figure
F
4
)
Side vertical laser line
(Figure
F
5
)
When the laser is not in use, slide the Power/Transport
Lock switch to the left in the OFF/Locked position. If
the Power/Transport Lock switch is not placed in the
lock position, all 4 LEDs will continuously ash on the
Battery Meter.
Checking Laser Accuracy
The laser tools are sealed and calibrated at the factory.
It is recommended that you perform an accuracy check
prior to using the laser for the rst time (in case the
laser was exposed to extreme temperatures) and then
regularly to ensure the accuracy of your work. When
performing any of the accuracy checks listed in this
manual, follow these guidelines:
Use the largest area/distance possible, closest to the
operating distance. The greater the area/distance,
the easier to measure the accuracy of the laser.
Place the laser on a smooth, at, stable surface that
is level in both directions.
Mark the center of the laser beam.
Horizontal Beam - Scan Direction
Checking the horizontal scan calibration of the laser
requires two walls 30 (9m) apart. It is important to
conduct a calibration check using a distance no shorter
than the distance of the applications for which the tool
will be used.
1.
Place the laser against the end of the wall on a
smooth, at, stable surface that is level in both
directions (Figure
K
1
).
2.
Move the Power/Transport Lock switch to the right
to turn the laser ON.
3.
Press to turn on the horizontal beam.
4.
At least 30 (9m) apart along the laser beam, mark
a
and
b
.
5.
Turn the laser 180º.
6.
Adjust the height of the laser so the center of the
beam is aligned with
a
(Figure
K
2
).
7.
Directly above or below
b
, mark
c
along the laser
beam (Figure
K
3
).
8.
Measure the vertical distance between
b
and
c
.
9.
If your measurement is greater than the Allowable
Distance Between
b
and
c
for the
corresponding Distance Between Walls in the
following table, the laser must be serviced at an
authorized service center.
Distance
Between Walls
Allowable Distance
Between
b
and
c
30’ (9m) 1/4” (6.0mm)
40’ (12m) 5/16” (8.0mm)
50’ (15m) 13/32” (10.0mm)

Other manuals for DeWalt DW089LG