Storage (Fig.K)
CAUTION: Turn on/off tool control switch
15
to the OFF
position (O). Disconnect from the power supply.
1. Empty the canister, refer to To Empty Canister
underOperation.
2. Clean the vacuum inside andoutside.
3. Clean or replace filters, refer toFilters.
4. Remove the hose
7
from the twist-lock hose inlet
10
and
close the inlet with the inlet plug
20
5. Put the ends of the suction hose together to prevent dirt
particles fromescaping.
6. Store the suction hose and the power cord as shown in the
illustration. Place the unit in a dry room and secure it from
unauthorizeduse.
NOTE: Plug inlet plug into inlet to keep debris inside
canister when suction hose is removed. You can also attach
the ends of the hose together and lock together with the
twist-lockend.
NOTE: After wet applications, the internal parts of the liquid
container must be dried beforestorage.
Cleaning
WARNING: Never use solvents or other harsh chemicals
for cleaning the non-metallic parts of the appliance. These
chemicals may weaken the materials used in these parts.
Never let any liquid get inside the machine; never immerse
any part of the appliance into aliquid.
1. Vacuum the outside of the dust extractor. For further
cleaning use a cloth dampened only with water and mild
soap ifnecessary.
2. After use dispose of cloth in an appropriatecontainer.
Lubrication
Your dust extractor requires no additionallubrication.
cleaned, are to be disposed of; such items shall be
disposed of in impervious bags in accordance with any
current regulation for the disposal of suchwaste.
Remove the outside of the machine. It should be
decontaminated by vacuum cleaning methods and
wiped clean or treated with sealant before being taken
out of a hazardous area. All the machine parts shall
be regarded as contaminated when removed from
the hazardous area and appropriate action taken to
prevent dustdispersal.
Filter
To Remove Filters (Fig.L, M)
1. Turn on/off tool control switch
15
to the OFF position ( )
and unplug cord fromoutlet.
2. Release canister latches
4
and remove vacuum head
3
from canister. Place vacuum head on a level surface
upsidedown.
3. For DWV905H, loosen the 2.5mm socket head screw
32
using
a T-10 bit, then remove the filter plate
33
from the filters as
shown in Fig. L. Do not reuse the Class H main filter element
after it has been removed from theunit.
4. Turn each filter
9
counterclockwise by gripping it on the
plastic end cover as shown in Fig. M, and carefully remove
from head, ensuring debris does not fall into mountinghole.
NOTE: Use care to not damage filtermaterial.
5. If the bottom side of the vacuum head needs to be cleaned,
use a cloth dampened with water and mild soap and allow
it to dry. Dispose of cloth in an appropriatecontainer.
6. Inspect filters for wear, tears or otherdamage.
WARNING: If there is any doubt on the condition of the
filters, they MUST be replaced. DO NOT continue use if
filters aredamaged. Class H filters should not get cleaned
manually outside of the unit.
WARNING: Never use compressed air or a brush to clean
filters, otherwise damage to the filter membrane will occur
which will allow dust to pass through the filter. If needed,
gently tap against a hard surface or rinse with room
temperature water and let air dry. Cleaning of the filters
is typically unnecessary, even if the filter is covered with
dust. The automatic filter cleaning system will maintain
maximum performance and continue to function. If visual
damage to the filter membrane exists, replace filters. Filters
typically last between six and twelve months depending
on use andcare.
To Install Filters (Fig.L, N)
1. Ensure filter seal
34
is in place and is secure
2. Line up filter threads
35
to vacuum head threads and using
moderate force, turn filter clockwise untiltight.
NOTE: Use care to not damage filtermaterial.
3. For DWV905H, replace the filter plate
33
and tighten the
screw
32
on top of theplate.
4. Place the vacuum head
3
onto the container and secure it
by closing the canister latches
4
.
Accessories
WARNING: Since accessories, other than those offered
by DeWALT, have not been tested with this product, use of
such accessories with this appliance could be hazardous.
To reduce the risk of injury, only DeWALT recommended
accessories should be used with thisproduct.
ACCESSORIES
DWV9340 Dust Class M Filter
DWV9345 Dust Class H Filter
DWV9315 Crush-proof hose
DWV9316 Anti-static hose;
diameter 32 mm
DWV9350 Floor Cleaning Kit
DWV9401 Paper bag
DWV9400 Plastic liner
DWV9402 Fleece bag
DWV9500 Vac Rack
DWV9510 ToughSystem®, TSTAK®
Vac Rack