3
Specifications
CONTENTS
WARNINGS ........................................................................2-3
HEATER SPECIFICATIONS ................................................... 3
OPERATING PRECAUTIONS ................................................ 4
SAFETY PRECAUTIONS ....................................................... 4
ODOR FADE WARNING ..................................................... 5-6
OPERATING INSTRUCTIONS ............................................... 6
MAINTENANCE, STORAGE AND SERVICE ......................... 7
WIRING DIAGRAMS .............................................................. 8
PARTS LISTS/EXPLODED VIEWS .................................... 9-12
WARRANTY ......................................................................... 13
INSTRUCTIONS FOR ORDERING PARTS .......................... 13
WARNING: RISK OF FIRE OR EXPLOSION
• Do not store or use gasoline or other ammable vapors and liquids in
the vicinity of this or any other appliance.
• WHAT TO DO IF YOU SMELL GAS:
• Open windows.
DO NOT try to light any appliance.
DO NOT operate any electrical switches.
DO NOT use any telephone in building. Immediately call the
local gas supplier from an outside telephone. Follow the gas
supplier’s instructions.
DO NOT touch any electrical switch; do not use any phone in your
building.
• If you cannot reach your gas supplier, call the Fire Department.
Model: DXH125FAV DXH150FAV
Rating: 75,000 - 125,000 Btu/Hr 110,000 - 150,000 Btu/Hr
(21.9 – 36.6 kW) (32.2 – 43.9 kW)
Fuel Consumption: 3.5 – 5.8 #/hr 5.1 – 6.9 #/hr
(1.59 – 2.63 kg/hr) (2.31 – 3.13 kg/hr)
Fuel Orifice Size 1.26 mm 1.40 mm
SPECIFICATIONS
Type of Gas: ..............For use with Propane Only
Gas Supply Pressure
to regulator .............Max.: Bottle Pressure
to regulator .............Min.: 5 psig (34.5 kPa)
regulator out ..........27.5" W.C. (6.84 kPa)
Electrical Input: ..........115V, 60 Hz, 1Ø, 3a
Min. Operating Voltage: 100V
Ignition: ...................... Direct Spark
Primary
Flame Control: .........Thermocouple Operated Gas Valve
High Temperature
Control: .................... 240°F (116°C)
Min. Ambient Temp. Rating 0°F (-17.8°C)