Configuring system settings Set system date and time
Digi TransPort® Routers User Guide
718
4. Click Apply.
Command line
Command Instance Parameter Values
Equivalent web
parameter
n/a n/a time hh [mm [ss [DD [MM [YYYY]]]]] Manually set the time.
sntp n server Valid hostname or IP address
sntp.timeserve.org
SNTP Server
sntp n pwrchk 0, 1
0=Off
1=On
Check on Power-up
sntp n interval 0-255 Update every h hours
Default=24
sntp n randintsecs 0-86400 Randomly between s1 and
s2 seconds
Use format [s1,s2]
For example, min 50, max
500 would be: [50,500]
sntp n offset -12 to +13 Offset from GMT.
sntp n dstonmon 0-12 Start: Month
Update for Daylight Saving
Time
0 disables daylight saving.
sntp n dstonday 0-31 Start: Day
sntp n dstonhr 0-23 Start: Hour
sntp n dstoffmon 0-12 End: Month
sntp n dstoffday 0-31 End: Day
sntp n dstoffhr 0-23 End: Hour
sntp n ntp 0, 1
0=SNTP
1=NTP
Default=OFF
ntp n driftppm -10000-+10000 Initial Drift Compensation
ntp n precision -10-0 Clock Precision Limit
ntp n inhibit_int Blank, PPP, Ethernet Disable NTP when
interface x,y is out of
service
x=Interface type