Repair of DGT 2010
Lever does not switch
When performing the functional test as described in the 1708 problem document, the numbers in the display
should change from 5 to 6 when operating the lever.
To enter this test you have to push the button and hold it when switching on the clock, push ►|| next.
Foto 1 The numbers that indicate the lever positon
If the numbers don't change the lever switch may be damaged or the magnet that operates the switch may
be out of place.
There is a simple test to check if the magnet in the lever is inplace:
Take out one of the corner screws out of the bottom.
Place it on the left side of the lever
If the magnet is OK the screw will be orientated like in the picture or 180 degrees rotated.
When the screw is oriented otherwise or will not be attracted to the lever at all, proceed with the following
steps.