EasyManua.ls Logo

DigiTech Midi - Page 12

DigiTech Midi
223 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RECEIVE ONE PROGRAM (01000010b 42h)
SYSX_HEADER 42h yy zz d(1) d(1)' ... d(n) d(n)' EOX
SYSX_HEADER 42h zz d(1)' ... d(n)' EOX (For IPS 33B only)
yy 0000000vb where v is bit 7 of the received program number - 1.
zz 0vvvvvvvb where v is bits 6 through 0 of the received
program number - 1.
d(c) 0000000vb where v is bit 7 of the cth byte of the received program.
d(c)' 0vvvvvvvb where v is bits 6 through 0 of the cth byte of the received
program.
The RECEIVE ONE PROGRAM procedure is used to load a program into the
DigiTech device. The number of program bytes to be received (n) is different
for each DigiTech device.

Related product manuals